Customization: | Available |
---|---|
Color: | Black |
Usage: | Fuel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Polypropylene(PP) insulation, Nitrile rubber(NBR) jacket, Fluoropolymer tape and synthetic braid covered
completely over the jacket, Full galvanized steel (or stainless steel or Monel) tape armour.
Performing Criterion:This cable is applicable for use in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV. The permissible working temperature is 90ºC(194ºF). The cable has the excellent ability of oil-resistance and corrosion-resistance.
Phase | Cross Section mm2 |
Conductor Diameter mm |
DC Resistance at 20ºC ≤ Ω/km |
Insulation Thickness mm 3kV 6kV |
Jacket Thickness mm 3kV 6kV |
Overall Size and Weight | 6kV |
kg/km | ||||||||||||||||||||
3KVmm×mm kg/km |
||||||||||||||||||||||||||||
mm×mm |
||||||||||||||||||||||||||||
3 | 16 | 1/4.62 | 1.16 | 1.9 | 2.3 | 1.0 | 1.0 | 14×37 | 1278 | 18×42 | 1390 | |||||||||||||||||
3 | 20 | 1/5.19 | 0.86 | 1.9 | 2.3 | 1.0 | 1.0 | 15×39 | 1449 | 19×44 | 1580 | |||||||||||||||||
3 | 33 | 1/6.54 | 0.56 | 1.9 | 2.3 | 1.0 | 1.0 | 16×44 | 1643 | 21×50 | 1760 | |||||||||||||||||
3 | 42 | 1/7.35 | 0.44 | 1.9 | 2.3 | 1.0 | 1.0 | 17×47 | 2158 | 22×54 | 2270 |
Cross Section |
Conductor Diameter mm |
3kV Insulation Resistance M Ω ·km |
3kV Leakage Current at 15.6ºC μA/km/kV |
6kV Insulation Resistance M Ω ·km |
6kV Leakage Current μA/km/kV |
DC Voltage Test For 5 Minutes |
||||||||||||||||||||||
mm2 | AWG | 3kV | 6kV | |||||||||||||||||||||||||
16 | 5 | 4.62 | 4500 | 0.278 | 5400 | 0.246 | ||||||||||||||||||||||
20 | 4 | 5.19 | 3380 | 0.295 | 3869 | 0.262 | 27kV | 35kV | ||||||||||||||||||||
33 | 2 | 6.54 | 2530 | 0.394 | 2922 | 0.328 | ||||||||||||||||||||||
42 | 1 | 7.35 | 2300 | 0.427 | 2658 | 0.361 |
Company Profile